Guide · Commercial refrigeration

Walk-In Cooler Not Cooling? Common Causes

When a walk-in climbs above 41°F, product is at risk. These are common causes in restaurant walk-ins, what you can safely check yourself and when to call a technician.

Need it fixed?
$125Commercial service call · diagnosis on site
Mon–Thu 8 am–7 pmFri 8 am–6 pmSat 9 am–4 pm · Sun 10 am–3 pm
980-332-2911
Guide

First: protect the product

The FDA Food Code requires cold-held food at 41°F or below. If the box is warming up, keep the door closed, move the most sensitive product to another cooler and call for service.

1. Dirty condenser coil

The condenser gets rid of the heat. When it is covered in dust and grease, the system runs longer and cools less, especially on hot days. It is one of the most common causes, and also one of the easiest to prevent with scheduled coil cleaning.

2. Iced-up evaporator or failed defrost

If the coil inside the box is a block of ice, air cannot pass through it. Usually a defrost timer, defrost heater, termination switch or drain line is the reason. Clearing the ice without fixing the cause only buys a few days.

3. Door and gasket problems

A door that does not close all the way, a torn gasket or missing strip curtains let warm, humid air in all day. That means more ice on the coil and a warmer box.

4. Evaporator or condenser fan motor

If a fan stops, airflow stops. You may hear the compressor running while the box keeps warming up.

5. Controls and thermostat

A thermostat set wrong, a failed sensor or a controller fault can make the system stop early or not start at all.

6. Refrigerant leak or compressor problem

Low refrigerant or a failing compressor needs a certified technician. Refrigerant work requires EPA 608 certification.

What you can check yourself

  • Is the door closing and sealing all the way?
  • Is the evaporator in the box covered with ice?
  • Is product blocking the airflow around the evaporator?
  • Is the condensing unit running, and is its coil visibly dirty?
  • Was the thermostat setting changed?

Do not chip ice off the coil with tools. It is easy to puncture a tube and turn a simple repair into a refrigerant leak.

When to call

If the box stays above 41°F, the coil keeps icing up or the system runs nonstop, call us. The commercial service call is $125, and you get the repair price before we start.

Walk-in warming up? Call now.

980-332-2911

Open every day. See walk-in cooler repair and maintenance plans.